BPS-1002

BPS-1002
Power input 115VAC 60 Hz, 1.45 amp.
Two (2) Class A or two (2) Class B FACP inputs
Field selectable 24VDC or 12VDC voltage regulated power limited outputs
Two (2) NC dry contact trigger inputs
24VDC or 12VDC rated @ 8 amp max total alarm current
2.5 amp max current per output
Separate 1 Amp auxiliary output with built-in and remote reset capability
Two (2) outputs may be paralleled for more power on an indicating circuit
Programmable supervised indicating circuit outputs:
Up to Four (4) Class B or Two (2) Class A or One (1)
Class A and Two (2) Class BThermal and short circuit protection with auto reset
Built-in charger for sealed lead acid or gel type batteries
Automatic switchover to stand-by battery when AC Fails
Zero voltage drop when switching over to battery backup
PTC battery protection
AC fail supervision (form “C” contact, 1 amp / 28VDC). Factory set for 1 minute with optional 18 hour delay setting (field selectable)
Battery presence and low battery supervision (form “C” contact, 1 amp / 28VDC)
Input and output status LED indicators
2 wire horn/strobe Sync mode allows audible notification appliances (horns) to be silenced while visual notification appliances (strobes) continue to operate
Temporal Code 3, Steady Mode, Input to Output Follower Mode (maintains synchronization of notification appliances circuit)
Horn/Strobe sync protocols include Mircom, Amseco, Gentex, System Sensor, Faraday and Wheelock
March Time
Compatible with 12 or 24VDC fire panels.
Filtered and electronically regulated output
Output loop supervision steered to input 1 or input 2
Common trouble input and output
Ground fault detection
Unit includes power supply, red enclosure, cam lock, open frame transformer and battery leads
46%
Details
SKU SKU16171
Weight 17.00 lbs
 
Price: $425.00
Options
Quantity
Add to wish list

Send to friend

: *
: *
: *
 

Customer feedback

Customer Reviews
Product rating
  • Author: Frank Z
    I bought it here, but i'm little bit angry bacause today i found it cheaper here: http://topamshop.com
Add your review here
: *
Product rating: *
: *
Maximum review length is 2000 characters
Type the characters you see in the picture. (If you do not see any picture here, please enable images in your web browser options and refresh this page):